LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2013 >> Legacy Premium, Automatic CVT Trans >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC System (Heater, Ventilator And A/C) >> Blower Resistor (Manual A/C Model) >> Inspection

Blower Resistor (Manual A/C Model): Inspection

  1. Disconnect the blower resistor connector.
  2. Check the resistance between blower resistor terminals.

    Preparation tool: Circuit tester 

    Fig 1: Identifying Blower Resistor Terminals
    G06652943Courtesy of SUBARU OF AMERICA, INC.
    Terminal No. Standard
    4 - 2 Approx. 0.44 Ω
    4 - 3 Approx. 1.12 Ω
    4 - 1 Approx. 2.92 Ω
  3. Replace the blower resistor if the inspection result is not within the standard value.