LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2013 >> Legacy Premium, Automatic CVT Trans >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC System (Heater, Ventilator And A/C) >> Ambient Sensor >> Inspection

Ambient Sensor: Inspection

Preparation tool: 

Circuit tester 

  1. Visually check the ambient sensor for dirt or damage, and clean or replace as necessary.
  2. Check the resistance between ambient sensor terminals.
    CAUTION: During inspection, be careful not to touch the sensor end in order to avoid misjudgment due to body temperature.
    Fig 1: Checking Resistance Between Ambient Sensor Terminals 1 And 2
    G08546130Courtesy of SUBARU OF AMERICA, INC.
    Terminal No. Inspection conditions Standard
    1 - 2 10°C 3.12 - 3.70 kΩ
    15°C 2.49 - 2.88 kΩ
    20°C 2.00 - 2.26 kΩ
    25°C 1.62 - 1.79 kΩ
    30°C 1.32 - 1.42 kΩ
    35°C 1.08 - 1.14 kΩ
    40°C 0.89 - 0.92 kΩ
    45°C 0.74 - 0.75 kΩ
    50°C 0.62 - 0.62 kΩ
    55°C 0.52 - 0.51 kΩ
    60°C 0.44 - 0.42 kΩ
  3. Replace the ambient sensor if the inspection result is not within the standard value.