Trouble causes
- UART communication failure
- A/C control panel failure
- Mode door actuator failure
- Compressor failure
- Intake door actuator failure
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK A/C CONTROL PANEL.
|
Does "Mode Door Actuator Position Target" indicate 100%, "Variable Flow Change Solenoid Duty" indicate 0% or more and "Fresh/Recircle Air Door Actuator Position Target" indicate 100% respectively? | Go to step 2 . | Replace the A/C control panel. Refer to REMOVAL . |
| 2 CHECK MODE DOOR ACTUATOR. With the DEF switch ON, check the mode door operation. |
Does the air come out from the DEF outlet opening? | Go to step 3 . | Refer to UNABLE TO SWITCH VENTS . |
| 3 CHECK INTAKE DOOR ACTUATOR. With the DEF switch ON, check the FRESH/RECIRC door operation. |
Does the FRESH/RECIRC door operate normally? | Go to step 4 . | Refer to UNABLE TO SWITCH SUCTION VENTS . |
| 4 CHECK COMPRESSOR. With the DEF switch ON, check the compressor operation. |
Does the compressor operate? | System is normal. | Refer to COLD AIR DOES NOT COME OUT EVEN WHEN THE A/C SWITCH IS PRESSED. THE GLASS CANNOT BE DEFOGGED (COMPRESSOR DOES NOT OPERATE (VARIABLE)) . |