Operating Mode Table
| Display screen | Blower fan | Mode door | FRESH/RECIRC door | A/C compressor | Air mix door |
|---|---|---|---|---|---|
| 31 | LO | FACE | FRESH | OFF | Maximum cool |
| 32 | LO | FACE | RECIRC | ON | Maximum cool |
| 33 | M1 | FACE | RECIRC | ON | Maximum cool |
| 34 | M1 | B/L | FRESH | ON | 50% |
| 35 | M1 | FOOT | FRESH | ON | 50% |
| 36 | M3 | FOOT | FRESH | ON | Maximum hot |
| 37 | M3 | F/D | FRESH | ON | Maximum hot |
| 38 | HI | DEF | FRESH | ON | Maximum hot |