Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
- Abnormality Judgment
Judge as NG when the following conditions are established.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Rich | |
| Main feedback learning value | < -0.01 |
| Sub feedback learning value | < -0.03 |
| When any one of the followings is established. | |
|
> 20 time(s) |
|
> 255 time(s) |
|
> 20 time(s) |
|
> 255 time(s) |
| Lean | |
| Main feedback learning value | > 0.01 |
| Sub feedback learning value | < -0.012 |
| When any one of the followings is established. | |
|
> 20 time(s) |
|
> 255 time(s) |
|
> 20 time(s) |
|
> 255 time(s) |
Time Needed for Diagnosis: 1000 engine revs.
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the following conditions are established.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Rich | |
| Main feedback learning value | ≥ -0.01 |
| or | |
| Sub feedback learning value | ≥ -0.03 |
| or | |
| All of the following conditions are established. | |
|
≤ 20 time(s) |
|
≤ 255 time(s) |
|
≤ 20 time(s) |
|
≤ 255 time(s) |
| Lean | |
| Main feedback learning value | ≤ 0.01 |
| or | |
| Sub feedback learning value | ≥ -0.012 |
| or | |
| All of the following conditions are established. | |
|
≤ 20 time(s) |
|
≤ 255 time(s) |
|
≤ 20 time(s) |
|
≤ 255 time(s) |
Time Needed for Diagnosis: 1000 engine revs.