LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2013 >> Legacy Premium, Automatic CVT Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 11 (Engine Controls (Diagnostics) (H6DO)) >> Diagnostic Procedure with Diagnostic Trouble Code (DTC) >> DTC P0452: Evaporative Emission System Pressure Sensor/Switch Low >> Wiring Diagram

DTC P0452: Evaporative Emission System Pressure Sensor/Switch Low: Wiring Diagram

WARNING: This page is about a different variant/trim than selected.
DIAGNOSTIC PROCEDURE

Step Check Yes No
1 CHECK CURRENT DATA. 
  1. Turn the ignition switch to ON.
  2. Read the value of «Atmosphere Pressure» using the Subaru Select Monitor or a general scan tool.
NOTE:
  • Subaru Select Monitor

    For detailed operation procedures, refer to "READ CURRENT DATA FOR ENGINE". Refer to SUBARU SELECT MONITOR .

  • General scan tool

    For detailed operation procedures, refer to the general scan tool operation manual.

Is the value in «Atmosphere Pressure» 34 kPa (255 mmHg, 10 inHg) or less? Go to step . Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
2 CHECK POWER SUPPLY OF LEAK CHECK VALVE ASSEMBLY. 
  1. Turn the ignition switch to OFF.
  2. Disconnect the connector from the leak check valve assembly.
  3. Turn the ignition switch to ON.
  4. Measure the voltage between the leak check valve assembly connector and chassis ground.

    Connector & terminal 

    (R400) No. 6 (+) - Chassis ground (-): 

Is the voltage 4.5 V or more? Go to step . Repair the harness and connector.
NOTE: In this case, repair the following item:
  • Open circuit in harness between ECM and the leak check valve assembly connector
  • Poor contact of ECM connector
  • Poor contact of coupling connector
3 CHECK HARNESS BETWEEN ECM AND LEAK CHECK VALVE ASSEMBLY CONNECTOR. 
  1. Turn the ignition switch to OFF.
  2. Disconnect the connector from ECM.
  3. Measure the resistance between ECM and chassis ground.

    Connector & terminal 

    (B136) No. 21 - Chassis ground: 

Is the resistance 1 MΩ or more? Go to step . Repair the short circuit to ground in harness between ECM and leak check valve assembly connector.
4 CHECK FOR POOR CONTACT. 
Check for poor contact of leak check valve assembly connector.
Is there poor contact in the leak check valve assembly connector? Repair the poor contact in the leak check valve assembly connector. Replace the leak check valve assembly. Refer to LEAK CHECK VALVE ASSEMBLY .