Electrical Specification
WARNING: This page is about a different car, the 2013 Subaru Forester. However, it is still accessible from the selected car via links, so may be relevant.
| Terminal No. | Description | Measuring condition | Standard |
|---|---|---|---|
| 1 | Mode door actuator #4 | Actuator operating | 8 V or more |
| 2 | Mode door actuator #3 | Actuator operating | 8 V or more |
| 3 | Mode door actuator #2 | Actuator operating | 8 V or more |
| 4 | Mode door actuator #1 | Actuator operating | 8 V or more |
| 6 | Intake door actuator (FRESH) | FRESH mode | 1 V or less |
| 7 | Intake door actuator (MIX) | MIX mode | 1 V or less |
| 8 | Intake door actuator (RECIRC) | RECIRC mode | 1 V or less |
| 9 | Blower fan ON signal | Blower fan is ON | 1 V or less |
| 11 | A/C cut-off signal | A/C is cut off | 1 V or less |
| 14 | GND for sensors | Always | 1 V or less |
| 15 | ACC power supply | ACC ON | Battery voltage |
| 16 | Sunload sensor | Sunlight is contacting sensor | 1 - 4 V |
| 17 | RECIRC sensor | Ignition switch ON | 25°C: 2.5 V |
| 18 | Post evaporator sensor | Depends on temperature after the evaporator. | 1 - 4.5 V |
| 19 | CAN Lo | Digital signal; can not be measured | - |
| 20 | CAN Hi | Digital signal; can not be measured | - |
| 21 | Air mix door actuator LH #4 (with left/right independent air conditioning function) | Actuator operating | 8 V or more |
| 22 | Air mix door actuator LH #3 (with left/right independent air conditioning function) | Actuator operating | 8 V or more |
| 23 | Air mix door actuator LH #2 (with left/right independent air conditioning function) | Actuator operating | 8 V or more |
| 24 | Air mix door actuator LH #1 (with left/right independent air conditioning function) | Actuator operating | 8 V or more |
| 25 | Air mix door actuator #4 (without left/right independent air conditioning function) or air mix door actuator RH #4 (with left/right independent air conditioning function) | Actuator operating | 8 V or more |
| 26 | Air mix door actuator #3 (without left/right independent air conditioning function) or air mix door actuator RH #3 (with left/right independent air conditioning function) | Actuator operating | 8 V or more |
| 27 | Air mix door actuator #2 (without left/right independent air conditioning function) or air mix door actuator RH #2 (with left/right independent air conditioning function) | Actuator operating | 8 V or more |
| 28 | Air mix door actuator #1 (without left/right independent air conditioning function) or air mix door actuator RH #1 (with left/right independent air conditioning function) | Actuator operating | 8 V or more |
| 31 | BATT | Always | Battery voltage |
| 32 | IGN | Ignition ON | Battery voltage |
| 34 | GND | Always | 1 V or less |
| 36 | A/C ON signal | A/C is operating | 8 V or more |
| 35 | ILL- | Illumination ON (measure between 37 - 35) | Battery voltage |
| 37 | ILL+ | ||
| 39 | Rr defogger switch output | When the rear defogger switch is ON | 1 V or less |
| 40 | Fan control signal | Ignition switch: ON, Blower switch: ON | 8 V or more |