Combination Valve One Side Closed Pulse Diagnosis
Perform close stuck diagnosis of the LH combination valve using delivery pipe pressure pulse when the RH combination valve is closed.
Calculate the voltage pulse of the pump delivery pipe pressure when the RH combination valve is closed and the LH combination valve is open. The calculation of delivery pipe pressure should be large when the LH combination valve is open. Judge that the LH combination valve is close stuck if the calculation is small.
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| Pulse calculated value when the RH combination valve is closed | < Value of Map 1 | P2443 |
Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| Pulse calculated value when the RH combination valve is closed | ≥ Value of Map 1 | P2443 |
Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms
Perform close stuck diagnosis of the RH combination valve using delivery pipe pressure pulse when the LH combination valve is closed.
Calculate the voltage pulse of the pump delivery pipe pressure when the LH combination valve is closed and the RH combination valve is open. The calculation of delivery pipe pressure should be large when the RH combination valve is open. Judge that the RH combination valve is close stuck if the calculation is small.
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| Pulse calculated value when the LH combination valve is closed | < Value of Map 2 | P2441 |
Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| Pulse calculated value when the LH combination valve is closed | ≥ Value from Map 2 | P2441 |
Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms