Combination Valve Changeover Pressure Diagnosis
Perform the RH combination valve stuck closed diagnosis with the variation of delivery pipe pressure when the RH combination valve turns closed → open.
Delivery pipe pressure should vary when the RH combination valve turns closed → open. When the variation is small, determine that the RH combination valve is stuck closed.
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| Pressure variation value when the RH combination valve is switched | < Value of Map 6 | P2441 |
Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| Pressure variation value when the RH combination valve is switched | ≥ Value of Map 6 | P2441 |
Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms
Perform the LH combination valve stuck closed diagnosis with the variation of delivery pipe pressure when the LH combination valve turns open → closed.
Delivery pipe pressure should vary when the LH combination valve turns open → closed. When the variation is small, determine that the LH combination valve is stuck closed.
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| Pressure variation value when the LH combination valve is switched | < Value of Map 7 | P2443 |
Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| Pressure variation value when the LH combination valve is switched | ≥ Value of Map 7 | P2443 |
Time Needed for Diagnosis: 4000 ms + 992 ms + 992 ms + 992 ms