Enable Conditions
WARNING: This page is about a different car, the 2013 Subaru Forester. However, it is still accessible from the selected car via links, so may be relevant.
ENABLE CONDITION
| Secondary Parameters | Enable Conditions |
|---|---|
| Activation of soaking timer | Completed |
| Battery voltage | ≤ 10.9 V |
| Ignition switch | OFF |
| Engine coolant temperature | ≤ 4.4 °C (39.9 °F) |
| and | |
| < 45 °C (113 °F) | |
| Atmospheric pressure | ≤ 75 kPa (563 mmHg, 22.2 inHg) |
| and | |
| < 110 kPa (825 mmHg, 32.5 inHg) | |
| EVAP conc. learning during previous driving cycle | Done |
| Learning value of EVAP conc. during previous driving cycle | ≥ 0.2 |
| Accumulated purge amount during previous driving cycle | ≤ Value of Map 1 |
MAP 1
| Engine coolant temperature °C (°F) | 0 (32) | 30 (86) | 50 (122) |
| Accumulated purge amount during previous driving cycle g (oz) | 500 (17.64) | 500 (17.64) | 8000 (282.16) |