DTC P2442 Secondary Air Injection System Switching Valve Stuck Open (Bank2): Wiring Diagram
WARNING: This page is about a different car, the 2013 Subaru Forester. However, it is still accessible from the selected car via links, so may be relevant.
Engine electrical system, turbo model < Refer to appropriate SYSTEM WIRING DIAGRAM. >
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK SECONDARY AIR COMBINATION VALVE FUSE. Check if the secondary air combination valve fuse (10 A) is blown out. |
Is the fuse blown out? | Go to step 2. | Go to step 3. |
2 CHECK HARNESS BETWEEN RELAY HOLDER AND SECONDARY AIR COMBINATION VALVE LH CONNECTOR.
|
Is the resistance 1 MΩ or more? | Replace the fuse with a new part, and connect the secondary air combination valve LH connector. Go to step 3. |
Repair the ground short circuit of harness between relay holder and secondary air combination valve LH connector. |
3 CHECK SECONDARY AIR COMBINATION VALVE LH OPERATION.
|
Does the secondary air combination valve LH repeatedly switch to ON and OFF? | Go to step 4. | Go to step 6. |
| 4 CHECK DUCT BETWEEN SECONDARY AIR PUMP AND SECONDARY AIR COMBINATION VALVE LH. Check the duct between the secondary air pump and secondary air combination valve LH. |
Is there damage, clog or disconnection of the duct? | Replace, clean or connect the duct. | Go to step 5. |
| 5 CHECK PIPE BETWEEN SECONDARY AIR COMBINATION VALVE LH AND CYLINDER HEAD. Check the pipe between the secondary air combination valve LH and cylinder head. |
Is there damage, clog or disconnection of the pipe? | Replace, clean or connect the pipe. | Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
NOTE:
In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
|
6 CHECK POWER SUPPLY TO SECONDARY AIR COMBINATION VALVE LH.
|
Does the voltage repeatedly change between 10 V and 0 V? | Replace the secondary air combination valve LH. < Refer to SECONDARY AIR COMBINATION VALVE . > | Go to step 7. |
| 7 CHECK HARNESS BETWEEN SECONDARY AIR COMBINATION VALVE LH AND CHASSIS GROUND. Measure the resistance between the secondary air combination valve LH connector and chassis ground. Connector & terminal (E40) No. 1 - Chassis ground: |
Is the resistance less than 5 Ω? | Go to step 8. | Repair the open circuit in harness between secondary air combination valve LH connector and chassis ground. |
8 CHECK HARNESS BETWEEN SECONDARY AIR COMBINATION VALVE RELAY 2 AND SECONDARY AIR COMBINATION VALVE LH CONNECTOR.
|
Is the resistance less than 1 Ω? | Go to step 9. | Repair the harness and connector.
NOTE:
In this case, repair the following item:
|
9 CHECK SECONDARY AIR COMBINATION VALVE RELAY 2.
|
Is the resistance less than 1 Ω? | Go to step 10. | Replace the secondary air combination valve relay 2. < Refer to ELECTRICAL COMPONENT LOCATION . > |
| 10 CHECK SECONDARY AIR COMBINATION VALVE RELAY 2. Measure the resistance between the secondary air combination valve relay 2 terminals with the battery disconnected. Terminals No. 7 - No. 8: |
Is the resistance 1 MΩ or more? | Go to step 11. | Replace the secondary air combination valve relay 2. < Refer to ELECTRICAL COMPONENT LOCATION . > |
11 CHECK SECONDARY AIR COMBINATION VALVE RELAY 2 POWER SUPPLY.
|
Is the voltage 10 V or more? | Go to step 12. | Repair the open or ground short circuit of power supply circuit. |
12 CHECK HARNESS BETWEEN ECM AND SECONDARY AIR COMBINATION VALVE RELAY 2 CONNECTOR.
|
Is the resistance less than 1 Ω? | Go to step 13. | Repair the harness and connector.
NOTE:
In this case, repair the following item:
|
| 13 CHECK HARNESS BETWEEN ECM AND SECONDARY AIR COMBINATION VALVE RELAY 2 CONNECTOR. Measure the resistance between the secondary air combination valve relay 2 connector and chassis ground. Connector & terminal (F9) No. 9 - Chassis ground: |
Is the resistance 1 MΩ or more? | Repair the poor contact of ECM connector. | Repair the short circuit to ground in harness between ECM and secondary air combination valve relay 2 connector. |