  1. Attach the PCV hose assembly to the PCV connector.
    Fig 1: Locating PCV Hose Assembly Clip
    G08570177Courtesy of SUBARU OF AMERICA, INC.
  2. Install the PCV hose assembly onto the cylinder block RH and cylinder block LH.
    NOTE: Use a new clamp for the PCV hose assembly, fit the cut out in the ST with the protrusion on the clamp as shown in the figure, and lock the clamp.

    ST 18353AA000 CLAMP PLIERS

    Fig 2: Locking Clamp Using Clamp Pliers
    G08570176Courtesy of SUBARU OF AMERICA, INC.
  3. Install the tumble generator valve assembly. < Refer to INSTALLATION , Tumble Generator Valve Assembly. >