Refrigerant Leak Check: Inspection
WARNING: This page is about a different car, the 2013 Subaru Forester. However, it is still accessible from the selected car via links, so may be relevant.
- Operate the A/C system for approx. 10 minutes, and check that the high-side pressure shows at least 690 kPa (7.03 kgf/cm2 , 100 psi). Then stop the engine to start the leak test.
- Starting from the connection between high-pressure pipe and evaporator, check the system for leaks along the high-pressure side through the compressor. The following items must be checked thoroughly.
- Check the joint and seam between pressure switch (triple pressure switch) and high-pressure pipe.
- Check the connections between condenser and pipes, and welded joints on the condenser.
NOTE: The leak tester may detect the oil on the condenser fins as a leak.- Check the joint between compressor and hoses.
- Check the machined area of the compressor and other joints on the compressor.
- Check the compressor shaft seal at the area near the center of compressor clutch pulley.
NOTE: Shaft seals may show a slight amount of leakage, about 3 g (0.1 oz) per year. This is not a problem. - Starting from the connection between low-pressure pipe and evaporator, check the system for leakage along the low-pressure side through the compressor. The following items must be checked thoroughly.
- Connection between 2 parts
- Connection between pipe and plate
- Visually check the rubber area of the flexible hose for cracks. Check the entire length of the flexible hose, especially the connection with the metal hose end.CAUTION: Carefully check the external surface of hoses and pipes at approx. 25 mm (0.98 in) per second.
- Disconnect the drain hose from the heater case, and check the hose end for at least 10 seconds. After the test is finished, reconnect the drain hose.
- Turn the ignition key to the ON position, and run the blower at high speed for approx. 1 minute. Stop the blower and check the ventilation grille on the instrument panel. While moving the tester closer to the grille, run the blower for 1 or 2 seconds, then stop it. Check the grille at that position for at least 10 seconds.
- Check the valve in the service port.
- Visually check the rubber seal in the service port cap.