Unit Inspection

WARNING: This page is about a different car, the 2013 Subaru Forester. However, it is still accessible from the selected car via links, so may be relevant.

Preparation tool: Circuit tester 

  1. Check the resistance between evaporator sensor terminals.
    Fig 1: Checking Resistance Between Evaporator Sensor Terminals
    G08316206Courtesy of SUBARU OF AMERICA, INC.
    Terminal No. Inspection conditions Standard
    1 - 2 -20°C 15.37 - 16.62 kΩ
    -15°C 12.09 - 12.87 kΩ
    -10°C 9.576 - 10.05 kΩ
    -5°C 7.636 - 7.899 kΩ
    0°C 6.132 - 6.256 kΩ
    5°C 4.891 - 5.057 kΩ
    10°C 3.928 - 4.113 kΩ
    15°C 3.174 - 3.366 kΩ
    20°C 2.581 - 2.77 kΩ
    25°C 2.111 - 2.292 kΩ
    30°C 1.737 - 1.907 kΩ
    35°C 1.437 - 1.595 kΩ
    40°C 1.195 - 1.34 kΩ
  2. Replace the evaporator sensor if the inspection result is not within the standard value.