  1. Disconnect the blower resistor connector.
  2. Check the resistance between blower resistor terminals.
    Fig 1: Identifying Blower Resistor Connector Terminals
    G05663172Courtesy of SUBARU OF AMERICA, INC.
    Terminal No. Standard
    4 and 3 Approx. 0.43 Ω
    4 and 2 Approx. 1.03 Ω
    4 and 1 Approx. 3.0 Ω
  3. Replace the blower resistor if the inspection result is not within the standard value.