WARNING: This page is about a different car, the 2013 Subaru Forester. However, it is still accessible from the selected car via links, so may be relevant.
  1. Disconnect the blower motor connector.
  2. Connect the battery positive (+) terminal to terminal No. 2 of blower motor connector, and negative (-) terminal to terminal No. 1. Check that the blower motor rotates normally.
    Fig 1: Checking Blower Motor For Smooth Rotation
    G05663169Courtesy of SUBARU OF AMERICA, INC.
  3. If the blower motor does not operate normally, replace the blower motor.