Unit Inspection

WARNING: This page is about a different car, the 2013 Subaru Forester. However, it is still accessible from the selected car via links, so may be relevant.

Preparation tool: Circuit tester 

  1. Visually check the ambient sensor for dirt or damage, and clean or replace as necessary.
  2. Check the resistance between ambient sensor terminals.
    CAUTION: During inspection, be careful not to touch the sensor end in order to avoid misjudgment due to body temperature.
    Fig 1: Checking Resistance Between Ambient Sensor Terminals
    G08316196Courtesy of SUBARU OF AMERICA, INC.
    Terminal No. Inspection conditions Standard
    1 - 2 10°C 5.82 - 6.18 kΩ
    15°C 4.58 - 4.87 kΩ
    20°C 3.64 - 3.86 kΩ
    25°C 2.91 - 3.09 kΩ
    30°C 2.35 - 2.49 kΩ
    35°C 1.9 - 2.02 kΩ
    40°C 1.56 - 1.65 kΩ
    45°C 1.28 - 1.36 kΩ
    50°C 1.06 - 1.12 kΩ
    55°C 0.88 - 0.93 kΩ
    60°C 0.74 - 0.78 kΩ
  3. Replace the ambient sensor if the inspection result is not within the standard value.