Enable Conditions
MONITOR A1: PRIMARY OXYGEN SENSOR FLUCTUATION
| Secondary Parameters | Enable Conditions |
|---|---|
| Closed loop control with primary oxygen sensor | Active |
| Engine speed | > 1400 rpm |
| and | |
| < 3000 rpm | |
| Engine coolant temperature | > 70 °C (158 °F) (Except for C6 model) |
| > 200 °C (392 °F) (C6 model) | |
| Intake air mass | ≥ 0.9 g/rev (0.03 oz/rev) (AT model) |
| ≥ 0.9 g/rev (0.03 oz/rev) (MT model) | |
| Integrated time of canister purge after engine start | ≥ 20.48 s |
| Learning value of EVAP density during purge | < 0.1 |
MONITOR B1: CRANKSHAFT SPEED FLUCTUATION
| Secondary Parameters | Enable Conditions |
|---|---|
| Misfire diagnosis monitor | Active |
| Engine coolant temperature | > 70 °C (158 °F) (Except for C6 model) |
| > 200 °C (392 °F) (C6 model) | |
| Idle switch | ON |
| Vehicle speed | ≤ 1.93 km/h (1.2 MPH) |
| Engine speed | > 475 rpm |
| and | |
| < 900 rpm (AT model) | |
| > 500 rpm | |
| and | |
| < 900 rpm (MT model) | |
| Intake air mass per revolution | < 0.5 g/rev (0.02 oz/rev) (AT model) |
| < 0.4 g/rev (0.01 oz/rev) (MT model) |