Ground Short Inspection (Bus "B" (Smart System Can)): Wiring Diagram
CAN communication system. See appropriate SYSTEM WIRING DIAGRAM article.
NOTE:
Main wiring harness or related lines may be shorted to ground, or shorted to ground in one of the control modules.
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK BETWEEN MAIN WIRING HARNESSES. Using the tester, measure the resistance between terminals. Connector & terminal (B280) No. 11 - Chassis ground: (B280) No. 21 - Chassis ground: |
Is the resistance 10 Ω or less? | Go to step 2 . | Currently, it is normal. |
| 2 CHECK CONTROL MODULE. With the tester connected, disconnect control module. Connector & terminal (B280) No. 11 - Chassis ground: (B280) No. 21 - Chassis ground: |
Did the resistance change to 10 Ω or more? | Replace the control module whose resistance has changed. | Repair or replace the short circuit of the main wiring harness and related lines between body integrated unit and keyless access CM. |