56 - 64 Ω (A/C Cm): Wiring Diagram
CAN communication system. See appropriate SYSTEM WIRING DIAGRAM article.
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK BETWEEN RELATED LINES AND MAIN WIRING HARNESS.
|
Is the resistance 400 Ω or more? | Related lines between A/C CM and main wiring harness is open, or main wiring harness is open at two places or more. | Go to step 2 . |
| 2 CHECK RELATED LINES. Using the tester, measure the resistance between terminals. Connector & terminal (i80) No. 4 - (B40) No. 6: (i80) No. 5 - (B40) No. 14: |
Is the resistance 10 Ω or more? | Repair or replace the open circuit of A/C CM related lines. | Check DTC of A/C CM. Refer to OPERATION . |