Monitor B1
Judge as NG when the following conditions are established.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Diagnostic Value2 (DV2) | > 45 time(s) (AT model except for PZEV) > 30 time(s) (MT model except for PZEV) > 17 time(s) (PZEV AT model) > 17 time(s) (PZEV MT model) |
Time Needed for Diagnosis: 1000 engine revs.
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the following conditions are established.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Diagnostic Value2 (DV2) | ≤ 45 time(s) (AT model except for PZEV) ≤ 30 time(s) (MT model except for PZEV) ≤ 17 time(s) (PZEV AT model) ≤ 17 time(s) (PZEV MT model) |
Time Needed for Diagnosis: 1000 engine revs.