LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2013 >> Forester XT Touring >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 14 (Diagnostic Trouble Code (DTC) Detecting Criteria (H4DO)) >> Diagnostic Trouble Code (DTC) Detecting Criteria >> DTC P0455 Evaporative Emission System Leak Detected (Large Leak) >> Leak Pressure Measurement

Leak Pressure Measurement

WARNING: This page is about a different variant/trim than selected.

Purpose: Measure the pressure (leak pressure) when the evaporative emission system becomes the negative pressure by the vacuum pump.

Store the pressure as a leak pressure while the following conditions are met.

JUDGMENT VALUE

Conditions for storing the leak pressure Threshold Value
When any one of the followings is established.  
  • Reference pressure for setting the target negative pressure - Pressure sensor output value
≤ Value of Map 4
  • Pressure sensor output value
< -5 kPa (-37.298 mmHg, -1.5 inHg)
  • Time of negative pressure introduction
≤ 900000 ms