LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2013 >> Forester X Limited >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 9 (Emission Control Systems (Aux. Emission Control Devices) (H4DOTC)) >> Secondary Air Pump >> Inspection >> Secondary Air Pump

Secondary Air Pump

WARNING: This page is about a different variant/trim than selected.
  1. Check that the secondary air pump has no deformation, cracks or other damages.
  2. Connect battery positive terminal to terminal No. 2 and battery ground terminal to terminal No. 1, and inspect the secondary air pump operation.
    CAUTION: Do not operate the secondary air pump continuously for 80 seconds or more.
    Fig 1: Connecting Battery Positive Terminal To Terminal No. 2 And Battery Ground Terminal To Terminal No. 1
    G06344929Courtesy of SUBARU OF AMERICA, INC.