LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2013 >> Forester X Limited >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 9 (Emission Control Systems (Aux. Emission Control Devices) (H4DOTC)) >> PCV Valve >> Installation

PCV Valve: Installation

WARNING: This page is about a different variant/trim than selected.
  1. Install the PCV valve to the PCV connector and connect the vacuum hose (A) to the PCV valve.
    NOTE: Use a new clamp for the PCV connector clamp, fit the cut out in the ST with the protrusion on the clamp as shown in the figure, and lock the clamp.

    ST 18353AA000 CLAMP PLIERS

    Fig 1: Removing/Installing PCV Hose Clamp Using Clamp Pliers
    G06650572Courtesy of SUBARU OF AMERICA, INC.
    Fig 2: Locating PCV Hose Assembly Pipe And Clamp
    G08540122Courtesy of SUBARU OF AMERICA, INC.
  2. Install the secondary air combination valve RH. < Refer to INSTALLATION , Secondary Air Combination Valve. >
  3. Install the intake manifold. < Refer to INSTALLATION , Intake Manifold. >
  4. Install the collector cover.