Diagnostic Procedure
WARNING: This page is about a different variant/trim than selected.
DIAGNOSTIC PROCEDURE
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK SECONDARY AIR COMBINATION VALVE.
|
Are there air leaks from the pipe connections? | Replace the secondary air combination valve on the side with the air leak. < Refer to SECONDARY AIR COMBINATION VALVE . > | Perform the diagnostic procedure of P2440. < Refer to DTC P2440 SECONDARY AIR INJECTION SYSTEM SWITCHING VALVE STUCK OPEN (BANK1) , Diagnostic Procedure with Diagnostic Trouble Code (DTC). > |