Ambient Sensor (Auto A/C Model): Inspection

Preparation tool: Circuit tester 

  1. Visually check the ambient sensor for dirt or damage, and clean or replace as necessary.
  2. Check the resistance between ambient sensor terminals.
    CAUTION: During inspection, be careful not to touch the sensor end in order to avoid misjudgment due to body temperature.
    Fig 1: Checking Resistance Between Ambient Sensor Terminals
    G07914495Courtesy of SUBARU OF AMERICA, INC.
    Terminal No. Inspection conditions Standard
    1 - 2 10°C 3.12 - 3.70 kΩ
    15°C 2.49 - 2.88 kΩ
    20°C 2.00 - 2.26 kΩ
    25°C 1.62 - 1.79 kΩ
    30°C 1.32 - 1.42 kΩ
    35°C 1.08 - 1.14 kΩ
    40°C 0.89 - 0.92 kΩ
    45°C 0.74 - 0.75 kΩ
    50°C 0.62 - 0.62 kΩ
    55°C 0.52 - 0.51 kΩ
    60°C 0.44 - 0.42 kΩ
  3. Replace the ambient sensor if the inspection result is not within the standard value.