Check Power Supply And Ground Circuit

DIAGNOSIS PROCEDURE

Step Check Yes No
1 CHECK POWER SUPPLY FOR COMBINATION METER. 
  1. Remove the combination meter. Refer to REMOVAL , Combination Meter.
  2. Disconnect the combination meter harness connector.
  3. Turn the ignition switch to ON.
  4. Measure the voltage between combination meter connector and chassis ground.

    Connector & terminal 

    (i10) No. 3 (+) - Chassis ground (-): 

Is the voltage 10 V or more? Go to step . Check the harness for open or short between the ignition switch and combination meter.
2 CHECK POWER SUPPLY FOR COMBINATION METER. 
Measure the voltage between combination meter connector and chassis ground.
Connector & terminal 
(i10) No. 1 (+) - Chassis ground (-): 
Is the voltage 10 V or more? Go to step . Check the harness for open or short between the fuse and combination meter.
3 CHECK GROUND CIRCUIT OF COMBINATION METER. 
  1. Turn the ignition switch to OFF.
  2. Measure the resistance of harness between combination meter connector and chassis ground.

    Connector & terminal 

    (i10) No. 15 - Chassis ground: 

    (i10) No. 16 - Chassis ground: 

Is the resistance less than 10 Ω? Replace the meter case assembly. Repair the wiring harness.