DTC P2006 Intake Manifold Runner Control Stuck Closed (Bank 1): DTC Detecting Condition
WARNING: This page is about a different variant/trim than selected.
- Immediately at fault recognition
- GENERAL DESCRIPTION Refer to GD(H4DOTC)-204, DTC P2006 INTAKE MANIFOLD RUNNER CONTROL STUCK CLOSED (BANK 1), Diagnostic Trouble Code (DTC) Detecting Criteria.
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK FOR ANY OTHER DTC ON DISPLAY. | Is any other DTC displayed? | Check the appropriate DTC using the "List of Diagnostic Trouble Code (DTC)". Refer to , LIST OF DIAGNOSTIC TROUBLE CODE (DTC) . | Go to step 2 . |
2 CHECK TUMBLE GENERATOR VALVE RH.
|
Is there any dirt or clogging with foreign objects in the tumble generator valve? | Clean the tumble generator valve. | Replace the tumble generator valve assembly RH. Refer to FU(H4DOTC)-47, Tumble Generator Valve Assembly. |