Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
- Abnormality Judgment
Judge as NG when the following conditions are established.
JUDGMENT VALUE CHARTMalfunction Criteria Threshold Value Battery voltage > 10.9 V Starter switch OFF Engine run bus off flag or error warning flag set (error) or ID received from control module connected to driving system CAN None during 500 milliseconds or Data updated from control module connected to driving system CAN None during 2000 milliseconds Time Needed for Diagnosis: 2 seconds
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
JUDGMENT VALUE CHARTMalfunction Criteria Threshold Value Battery voltage > 10.9 V Starter switch OFF Engine run bus off flag or error warning flag clear (No error) ID received from control module connected to driving system CAN Yes Data updated from control module connected to driving system CAN Yes Time Needed for Diagnosis: 1000 ms
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.