Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE CHARTMalfunction Criteria Threshold Value λ value > 1.15 Time Needed for Diagnosis: 10000 ms
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
JUDGMENT VALUE CHARTMalfunction Criteria Threshold Value λ value ≤ 1.15 Time Needed for Diagnosis: Less than 1 second