Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
- When the conditions during which the differences of AVCS target timing advance amount and AVCS actual timing advance amount is large continues for certain amount of time.
- When the differences of target timing advance amount and actual timing advance amount is calculated during AVCS control, and the difference per predetermined time is the specified value or larger.
- Abnormality Judgment
Judge as NG when the following conditions are established within the predetermined time.
Judgment Value
JUDGMENT VALUEMalfunction Criteria Threshold Value Σ(Target position - Actual position) > 4500 °CA (Bank 1)
> 4500 °CA (Bank 2)or Σ(Target position - Actual position) < -7000 °CA (Bank 1)
< -7000 °CA (Bank 2)Time Needed for Diagnosis: 30000 ms
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the following conditions are established within the predetermined time.
Judgment Value
JUDGMENT VALUEMalfunction Criteria Threshold Value Σ(Target position - Actual position) ≤ 4500 °CA (Bank 1)
≤ 4500 °CA (Bank 2)
and
≥ -7000 °CA (Bank 1)
≥ -7000 °CA (Bank 2)Time Needed for Diagnosis: 30000 ms