Fig 1: Malfunction Indicator Light - Wiring Diagram
G06647746Courtesy of SUBARU OF AMERICA, INC.
DIAGNOSTIC PROCEDURE

Step Check Yes No
1 CHECK HARNESS BETWEEN ECM AND COMBINATION METER CONNECTOR  .
  1. Turn the ignition switch to OFF.
  2. Disconnect the connector from ECM.
  3. Turn the ignition switch to ON.
Does the malfunction indicator light illuminate? Repair the ground short circuit of harness between ECM and combination meter connector. Replace the ECM. Ref. to ENGINE CONTROL MODULE (ECM) .