Check Illumination Circuit
DIAGNOSTIC PROCEDURE
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK BODY INTEGRATED UNIT OUTPUT DATA
. Connect the Subaru Select Monitor, and check the illumination ON/OFF data at the data monitor of the integrated unit. |
Is it operating properly? | Go to step 2 . | Follow the diagnosis for the integrated unit. Refer to BASIC DIAGNOSTIC PROCEDURE . |
2 CHECK COMBINATION METER BRIGHTNESS CHANGE
.
|
Does the brightness of the combination meter change? | Go to step 3 . | Replace the meter case assembly. |
3 CHECK CLOCK ILLUMINATION POWER SUPPLY
.
Connector & terminal (i59) No. 1 (+) - Chassis ground (-): |
Is the voltage 10 V or more? | Go to step 4 . | Check the harness for an open circuit between the fuse and clock. |
4 CHECK COMBINATION METER
.
|
Does the brightness change? | Replace the clock body. | Replace the meter case assembly. |