LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2009 >> Forester X, Standard >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 4 (Fuel Injection System (H4DOTC)) >> Fuel >> Procedure >> DRAINING FUEL (w/SUBARU SELECT MONITOR)

DRAINING FUEL (w/SUBARU SELECT MONITOR)

WARNING: This page is about a different variant/trim than selected.

(WITH SUBARU SELECT MONITOR) 

WARNING: Place "NO OPEN FLAMES" signs near the working area.
CAUTION: Be careful not to spill fuel.
NOTE:
  1. Release the fuel pressure. Refer to RELEASING OF FUEL PRESSURE , PROCEDURE, Fuel .
  2. Attach ST to the fuel delivery pipe and push ST in the direction of arrow mark to disconnect the fuel delivery hose.

    ST 42099AE000 QUICK CONNECTOR RELEASE

    CAUTION:
    • Be careful not to spill fuel.
    • Catch the fuel from hoses using a container or cloth.
    Fig 1: Identifying Fuel Delivery Pipe
    G05660529Courtesy of SUBARU OF AMERICA, INC.
  3. Connect ST to the fuel delivery hose.

    ST 18471AA000 FUEL PIPE ADAPTER

  4. Connect the gasoline proof hose to ST, and put the hose end into the container.
  5. Drive the fuel pump and drain the fuel using Subaru Select Monitor. Refer to FUEL PUMP CONTROL (ON/OFF DRIVE) , OPERATION, System Operation Check Mode .
    CAUTION: Be careful not to spill fuel.