LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2006 >> Legacy GT spec.B >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC System (Heater, Ventilator And A/C) >> Refrigerant Recovery Procedure >> Procedure

Refrigerant Recovery Procedure: Procedure

CAUTION:
  • During operation, be sure to wear protective goggles and protective gloves.
  • Connect the refrigerant recovery system with the manifold gauge set to discharge the refrigerant from the A/C system and recycle the gas.
  • When recycling the discharged refrigerant, keep service cans on hand. Because the recovery rate with the recovery system is approx. 90%, service cans are necessary to charge the refrigerant.
  • Follow the detailed operation procedure described in the operation manual attached to the refrigerant recovery system.
  1. Perform the compressor oil return operation. < Ref. to PROCEDURE , Compressor Oil. >
  2. Stop the engine.
  3. Make sure the valves on low-/high-pressure sides of manifold gauge set are fully closed.
    Fig 1: Identifying Manifold Gauge Set
    G05020359
  4. Install the low-/high-pressure hoses to the service ports on the low-/high-pressure sides of the vehicle respectively.
    Fig 2: Identifying Manifold Gauge Set
    G05020360
  5. Connect the center hose to the refrigerant recovery system.
  6. Follow the operation manual to activate the refrigerant recovery system.