LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2006 >> Legacy GT spec.B >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 5 (Fuel Injection (Fuel Systems) (H4SO)) >> 26.Fuel Sub Level Sensor >> B: Installation

B: Installation

WARNING: This page is about a different variant/trim than selected.

Install in the reverse order of removal.

NOTE:
  • Use a new gasket.
  • Make sure the sealing portion is free from fuel or foreign matter before installation.
  • Align protrusion (A) of the gasket to the position shown in the following figure.
  • Align protrusion (B) of the fuel sub level sensor to the cut out in the fuel sublevel sensor upper plate.
  • Tighten the bolts in the sequence shown in the figure, to the specified torque.

    Tightening torque: 

    4.4 N.m (0.45 kgf-m, 3.2 ft-lb) 

    Fig 1: Identifying Bolts Tighten Sequence
    G05016929
    Fig 2: Locating Sub Level Sensor Bolt
    G05016930