Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
Abnormality Judgment
Judge as NG when the continuous time of completing the malfunction criterion below is 10 seconds x 3 times.
Judgment Value
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Actual - Target engine speed | ≥ 200 rpm |
| Feedback value for ISC | Min. |
Time Needed for Diagnosis: 10 seconds x 3 times
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
Normality Judgment
Judge as OK and clear the NG when the continuous time of completing the malfunction criterion below becomes more than the time needed for diagnosis (10 seconds).
Judgment Value
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Actual - Target engine speed | < 200 rpm |