Enable Condition
WARNING: This page is about a different variant/trim than selected.
Diagnostic enable condition is established if the radiator fan changes from OFF → ON when all of the conditions below are met.
When one of the conditions below is not met, the diagnostic enable condition is not established.
ENABLE CONDITION CHART
| Secondary Parameters | Enable Conditions |
|---|---|
| Engine speed | 560 - 900 rpm |
| Idle switch | ON |
| Vehicle speed | < 2km/h(1.2MPH) |
| Battery voltage | ≥ 10.9 V |