Home >> Subaru >> 2006 >> Legacy GT spec.B >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 11 (Engine Controls - Engine (Diagnostics) (H4SO)) >> Diagnostic Procedure with Diagnostic Trouble Code (DTC) >> DTC P0447 Evaporative Emission Control System Vent Control Circuit Open

DTC P0447 Evaporative Emission Control System Vent Control Circuit Open

WARNING: This page is about a different variant/trim than selected.

DTC DETECTING CONDITION: 

CAUTION: After repairing or replacing the defective part, perform the Clear Memory Mode < Ref. to OPERATION , Clear Memory Mode. > and Inspection Mode < Ref. to PROCEDURE , Inspection Mode. >.

WIRING DIAGRAM: 

Fig 1: Evaporative Emission Control System Vent Control Circuit Open - Wiring Diagram
G05017586
DIAGNOSIS PROCEDURE

Step Check Yes No
1 CHECK OUTPUT SIGNAL OF ECM. 
  1. Turn the ignition switch to ON.
  2. Measure the voltage between ECM and chassis ground.

    Connector & terminal 

    (B136) No. 17 (+) - Chassis ground (-): 

Is the voltage more than 10 V? Go to step 2.  Go to step 3. 
2 CHECK POOR CONTACT. 
Check poor contact of ECM connector.
Is there poor contact in ECM connector? Repair the poor contact of ECM connector. Even if the malfunction indicator light illuminates, the circuit has returned to a normal condition at this time. (However, the possibility of poor contact still remains.)
NOTE: In this case, repair the following item:
  • Poor contact in drain valve connector
  • Poor contact in ECM connector
  • Poor contact of coupling connector
3 CHECK HARNESS BETWEEN DRAIN VALVE AND ECM CONNECTOR. 
  1. Turn the ignition switch to OFF.
  2. Disconnect the connectors from drain valve and ECM.
  3. Measure the resistance of harness between drain valve connector and chassis ground.

    Connector & terminal 

    (R143) No. 2 - Chassis ground: 

Is the resistance more than 1 MΩ? Go to step 4.  Repair the ground short circuit of harness between ECM and drain valve connector.
4 CHECK HARNESS BETWEEN DRAIN VALVE AND ECM CONNECTOR. 
Measure the resistance of harness between ECM and drain valve connector.
Connector & terminal 
(B136) No. 17 - (R143) No. 2: 
Is the resistance less than 1 Ω? Go to step 5.  Repair the harness and connector.
NOTE: In this case, repair the following item:
  • Open circuit of harness between ECM and drain valve connector
  • Poor contact of coupling connector
5 CHECK DRAIN VALVE. 
Measure the resistance between drain valve terminals.
Terminals No. 1 - No. 2: 
Is the resistance between 10 and 100Ω? Go to step 6.  Replace the drain valve. < Ref. to DRAIN VALVE . >
6 CHECK POWER SUPPLY TO DRAIN VALVE. 
  1. Turn the ignition switch to ON.
  2. Measure the voltage between drain valve and chassis ground.

    Connector & terminal 

    (R143) No. 1 (+) - Chassis ground (-): 

Is the voltage more than 10 V? Go to step 7.  Repair the harness and connector.
NOTE: In this case, repair the following item:
  • Open circuit of harness between main relay and drain valve
  • Poor contact of coupling connector
  • Poor contact of main relay connector
7 CHECK POOR CONTACT. 
Check poor contact in drain valve connector.
Is there poor contact in drain valve connector? Repair poor contact in drain valve connector. Contact the SOA service center.