DTC P0447 Evaporative Emission Control System Vent Control Circuit Open
WARNING: This page is about a different variant/trim than selected.
DTC DETECTING CONDITION:
- Detected when two consecutive driving cycles with fault occur.
- GENERAL DESCRIPTION < Ref. to DTC P0447 EVAPORATIVE EMISSION CONTROL SYSTEM VENT CONTROL CIRCUIT OPEN , Diagnostic Trouble Code (DTC) Detecting Criteria. >
CAUTION:
After repairing or replacing the defective part, perform the Clear Memory Mode < Ref. to
OPERATION , Clear Memory Mode. > and Inspection Mode < Ref. to
PROCEDURE , Inspection Mode. >.
WIRING DIAGRAM:
DIAGNOSIS PROCEDURE
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK OUTPUT SIGNAL OF ECM.
|
Is the voltage more than 10 V? | Go to step 2. | Go to step 3. |
| 2 CHECK POOR CONTACT. Check poor contact of ECM connector. |
Is there poor contact in ECM connector? | Repair the poor contact of ECM connector. | Even if the malfunction indicator light illuminates, the circuit has returned to a normal condition at this time. (However, the possibility of poor contact still remains.)
NOTE:
In this case, repair the following item:
|
3 CHECK HARNESS BETWEEN DRAIN VALVE AND ECM CONNECTOR.
|
Is the resistance more than 1 MΩ? | Go to step 4. | Repair the ground short circuit of harness between ECM and drain valve connector. |
| 4 CHECK HARNESS BETWEEN DRAIN VALVE AND ECM CONNECTOR. Measure the resistance of harness between ECM and drain valve connector. Connector & terminal (B136) No. 17 - (R143) No. 2: |
Is the resistance less than 1 Ω? | Go to step 5. | Repair the harness and connector.
NOTE:
In this case, repair the following item:
|
| 5 CHECK DRAIN VALVE. Measure the resistance between drain valve terminals. Terminals No. 1 - No. 2: |
Is the resistance between 10 and 100Ω? | Go to step 6. | Replace the drain valve. < Ref. to DRAIN VALVE . > |
6 CHECK POWER SUPPLY TO DRAIN VALVE.
|
Is the voltage more than 10 V? | Go to step 7. | Repair the harness and connector.
NOTE:
In this case, repair the following item:
|
| 7 CHECK POOR CONTACT. Check poor contact in drain valve connector. |
Is there poor contact in drain valve connector? | Repair poor contact in drain valve connector. | Contact the SOA service center. |