DTC C0064 Primary Suction Valve Malfunction In VDCCM&H/U
DTC DETECTING CONDITION:
- Defective harness connector
- Defective VDCH/U solenoid valve
TROUBLE SYMPTOM:
- ABS does not operate.
- EBD does not operate.
- VDC does not operate.
WIRING DIAGRAM:
DIAGNOSIS PROCEDURE
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK THE VDCCM&H/U INPUT VOLTAGE.
|
Is the voltage 10 - 15 V? | Go to step 2. | Repair the power supply circuit. |
2 CHECK THE VDCCM&H/U GROUND CIRCUIT.
|
Is the resistance less than 0.5 Ω? | Go to step 3. | Repair the VDCCM&H/U ground harness. |
| 3 CHECK POOR CONTACT OF CONNECTORS. | Is there poor contact in connector between generator, battery and VDCCM&H/U? | Repair the connector. | Go to step 4. |
4 CHECK THE VDCCM&H/U.
|
Is the same DTC displayed? | Replace the VDCCM&H/U. < Ref. to VDC CONTROL MODULE AND HYDRAULIC CONTROL UNIT (VDCCM&H/U) . > | Go to step 5. |
| 5 CHECK OTHER DTC DETECTION. | Is any other DTC displayed? | Perform the diagnosis according to DTC. | Temporary poor contact occurs. |