Diagnostic Method
- Abnormality Judgment
Judge as NG when the continuous time of completing the malfunction criteria below becomes 1 second or more.
Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Intake manifold pressure | ≥ Map 10 |
Map 10
MAP 10 SPECIFICATION
| Pa (kPa (mmHg, inHg)) | 56.7 (440,17.3) | 67.2 (504, 19.8) | 75.7 (568, 22.4) | 84.3 (632, 24.9) | 92.8 (696, 27.4) | 101.3 (760, 29.9) |
| Abnormal threshold kPa (mmHg, inHg) | 160.9 (1207,47.5) | 173.4 (1301,51.2) | 185.8 (1394,54.9) | 198.4 (1488,58.6) | 210.7 (1581,62.2) | 221.3 (1660,65.4) |
| Normal threshold kPa (mmHg, inHg) | 138.5 (1039,40.9) | 151.0 (1133,44.6) | 163.4 (1226,48.3) | 176.0 (1320,52.0) | 188.4 (1413,55.6) | 198.9 (1492,58.7) |
Time Needed for Diagnosis: 1 second
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
- Normality Judgment
Judge as OK and clear the NG when the malfunction criteria below are met.
Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Intake manifold pressure | < Map 10 |