Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
- Abnormality Judgment
Judge NG when the cumulative time until completing the malfunction criteria below becomes more than the time (0.5 seconds) needed for diagnosis.
- Judgment Value JUDGMENT VALUE (ABNORMALITY JUDGMENT)
Malfunction Criteria Threshold Value Terminal voltage when ECM outputs ON signal High Time Needed for Diagnosis : 0.5 seconds
Malfunction Indicator Light Illumination : Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge OK and clear the NG when the malfunction criteria below are completed.
- Judgment Value JUDGMENT VALUE (NORMALITY JUDGMENT)
Malfunction Criteria Threshold Value Terminal voltage when ECM outputs ON signal Low