Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
- Abnormality Judgment
Judge NG when the cumulative time until completing the malfunction criteria below becomes more than time needed for diagnosis.
- Normality Judgment
Judge OK and clear the NG when the malfunction criteria below are not completed.
- Judgment Value JUDGMENT VALUE
Malfunction Criteria Threshold Value DTC Terminal voltage level when ECM out-puts OFF signal Low level P1292
P1294
P1296
P1298Terminal voltage level when ECM out-puts ON signal High level P1293
P1295
P1297
P1299Time Needed for Diagnosis : 2.5 seconds
Malfunction Indicator Light Illumination : Illuminates as soon as malfunction occurs.