Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
- Abnormality Judgment
AT: Judge NG when the continuous time of condition which satisfies the malfunction criteria below becomes more than time needed for diagnosis (5 seconds).
- Judgment Value JUDGMENT VALUE (ABNORMALITY JUDGMENT)
Malfunction Criteria Threshold Value Switch signal ON (Low) "P" range / "N" range on AT OFF Any other switches on AT ON - Normality Judgment
AT: Judge OK and clear the NG when the malfunction criteria below are completed.
- Judgment Value JUDGMENT VALUE (NORMALITY JUDGMENT)
Malfunction Criteria Threshold Value Switch signal OFF (High) "P" range / "N" range on AT OFF Any other switches on AT ON MT: Judge NG when the number of times until completing the malfunction criteria below continue 3 times in a row, judge OK when turning to OFF or ON.
- Judgment Value JUDGMENT VALUE
Malfunction Criteria Threshold Value Neutral switch on MT ON not detected Driving condition change - Vehicle speed = 0 km/h (0 MPH) & engine speed 600 - 900 rpm
- Vehicle speed 64-106 km/h (40 - 66 MPH) & engine speed 1600 - 2550 rpm
Change a) to b)
Time Needed for Diagnosis:
AT: Normal reception from AT is 5 seconds
MT: 3 monitoring on MT
Malfunction Indicator Light Illumination : Illuminates when malfunction occurs in 2 continuous driving cycles.