Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
Perform the diagnosis when the conditions below were continued for 2 seconds.
- Except "P", "N", "R" ranges and inhibitor switch is normal.
- Engine speed is more than 3000 rpm.
- Vehicle speed is 30 km/h (19 MPH) and vehicle speed sensor is normal.
- Turbine speed is more than 600 rpm.
Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Output from turbine shaft speed | < 600 rpm |
Time Needed for Diagnosis : 2 seconds
Malfunction Indicator Light Illumination : Illuminates when malfunction occurs in 2 continuous driving cycles.