Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
- Abnormality Judgment
Judge NG when the cumulative time until completing the malfunction criteria below becomes more than the time needed for diagnosis.
- Judgment Value JUDGMENT VALUE (ABNORMALITY JUDGMENT)
Malfunction Criteria Threshold Value Actual - target engine speed ≥ 800 rpm ISC closed loop compensation value = MIN value
Time Needed for Diagnosis : 1 second
Malfunction Indicator Light Illumination : Illuminates as soon as malfunction occurs.
- Normality Judgment
Judge OK when one of the malfunction criteria below is completed.
- Judgment Value JUDGMENT VALUE (NORMALITY JUDGMENT)
Malfunction Criteria Threshold Value ISC closed loop compensation value # MIN value Cumulative time (actual - target engine speed) < 100 rpm ≥ 2 seconds Cumulative time (engine speed < target idle speed) ≥ 2 seconds