Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
- There is no tank pressure variation when there is fuel temperature variation of 7°C (45°F).
- There is no tank pressure variation even when there is fuel level variation of 2 l (0.5 US gal, 0.4 Imp gal) or more every 60 seconds.
Judge NG when both of the conditions above are experienced.
- Abnormality Judgment
Judge NG when both of the conditions below are experienced.
- Judgment Value JUDGMENT VALUE (ABNORMALITY JUDGMENT)
Malfunction Criteria Threshold Value Change of fuel temperature ≥ 7°C (45°F) Max. - min. tank pressure ≤ 100 Pa (0.75 mmHg, 0.03 inHg) Fuel level variation of 2 l (0.5 US gal, 0.4 Imp gal) or more per minute ≥ 10 times
Time Needed for Diagnosis : 10 times per minute
Malfunction Indicator Light Illumination : Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge OK when both of the conditions below are experienced, and clear NG.
- Judgment Value JUDGMENT VALUE (NORMALITY JUDGMENT)
Malfunction Criteria Threshold Value Max. - min. tank pressure (During fuel temperature variation of 7°C (45°F)) > 100 Pa (0.75 mmHg, 0.03 inHg) Change of fuel temperature ≥ 7°C (45°F) Max. - min. tank pressure (During time lapse below) > 100 Pa (0.75 mmHg, 0.03 inHg) Fuel level variation of 2 l (0.5 US gal, 0.4 Imp gal) or more per minute ≥ 10 times