Enable Condition
WARNING: This page is about a different variant/trim than selected.
Used for Abnormality Judgment
ENABLE CONDITION (ABNORMALITY JUDGMENT)
| Secondary Parameters | Enable Conditions |
|---|---|
| Closed loop control with rear oxygen sensor | In operation |
| Target output voltage of rear oxygen sensor | ≥ 0.6 V |
| Amount of intake air | ≥ 10g/s |
| Engine coolant temperature | ≥ 75°C (167°F) |
| Misfire detection during 200 engine revs. | ≤ 7 times |
| Compensation factor for front oxygen (A/F) sensor with main feedback control | Not in limit value |
| Battery voltage with main feedback control | > 10.9 V |
| 5 seconds or more fuel shutoff in decel. | Experienced |