Detect the malfunction of front oxygen (A/F) sensor heater.
Diagnosis is performed using A/F microcomputer, and communication is established between A/F microcomputer and main microcomputer. Judge NG when the data of heater malfunction NG is transmitted. Judge NG when the front oxygen (A/F) sensor element impedance is out of the standard value.