DTC P0108 - Manifold Absolute Pressure/Barometric Pressure Circuit High Input -
WARNING: This page is about a different variant/trim than selected.
- DTC DETECTING CONDITION:
- Detected simultaneously at occurrence of malfunction.
CAUTION: After repair or replacement of malfunctioning parts, conduct Clear Memory Mode < Ref. to OPERATION , CLEAR MEMORY MODE > and INSPECTION MODE < Ref. to OPERATION , INSPECTION MODE. > - WIRING DIAGRAM:
DIAGNOSTIC PROCEDURE
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK CURRENT DATA.
NOTE:
|
Is the measured value more than 119.5 kPa (896.5 mmHg, 35.29 inHg)? | Go to step 9. | Go to step 2. |
| 2 CHECK INPUT SIGNAL FOR ECM. Measure voltage between ECM connector and chassis ground. Connector & terminal (B135) No. 3 (+) - Chassis ground (-): |
Is the measured value more than 4.5 V? | Go to step 4. | Go to step 3. |
| 3 CHECK INPUT SIGNAL FOR ECM. Measure voltage between ECM connector and chassis ground. Connector & terminal (B135) No. 3 (+) - Chassis ground (-): |
Is the measured value more than 4.5 V when shaking harness and connector of ECM? | Repair poor contact in ECM connector. | Contact with SOA (distributor) service.
NOTE:
Inspection by DTM is required, because probable cause is deterioration of multiple parts.
|
| 4 CHECK INPUT SIGNAL FOR ECM. Measure voltage between ECM connector and chassis ground. Connector & terminal (B135) No. 15 (+) - Chassis ground (-): |
Is the measured value less than 0.2 V? | Go to step 6. | Go to step 5. |
| 5 CHECK INPUT SIGNAL FOR ECM. (USING SUBARU SELECT MONITOR.) Read data of atmospheric absolute pressure signal using Subaru Select Monitor.
NOTE:
|
Is the measured value more than 13.3 kPa (100 mmHg, 3.94 inHg) when shaking harness and connector of ECM? | Repair poor contact in ECM connector. | Go to step 6. |
6 CHECK HARNESS BETWEEN ECM AND PRESSURE SENSOR CONNECTOR.
|
Is the measured value more than 4.5 V? | Go to step 7. | Repair open circuit in harness between ECM and pressure sensor connector. |
7 CHECK HARNESS BETWEEN ECM AND PRESSURE SENSOR CONNECTOR.
|
Is the measured value more than 1 Ω? | Go to step 8. | Repair open circuit in harness between ECM and pressure sensor connector. |
| 8 CHECK POOR CONTACT. Check poor contact in pressure sensor connector. |
Is there poor contact in pressure sensor connector? | Repair poor contact in pressure sensor connector. | Replace pressure sensor. < Ref. to PRESSURE SENSOR . > |
9 CHECK HARNESS BETWEEN ECM AND PRESSURE SENSOR CONNECTOR.
NOTE:
|
Is the measured value more than 119.5 kPa (896.5 mmHg, 35.29 inHg)? | Repair battery short circuit in harness between ECM and pressure sensor connector. | Replace pressure sensor. < Ref. to PRESSURE SENSOR . > |